SCAR sewage composite exhaust valve
+
  • SCAR sewage composite exhaust valve

I. Product Overview   
This product is used at the highest point of the pipeline or where air is trapped to remove air from the pipe and ensure normal operation. If an air vent valve is not installed, the flowing liquid in the pipe will generate heat and cause air to form a short circuit, resulting in the pipeline's water output not meeting requirements. Secondly, when the pipeline is operating, power outages or pump stops will cause negative pressure in the pipeline, which may cause pipeline vibration or rupture. The (exhaust) air valve quickly draws air into the pipe to prevent pipeline vibration or rupture.
 

II. Working Principle   
When water enters the pipe, the plug stops at the bottom of the positioning frame and vents a large amount of air. When the air is exhausted, the water enters the valve and floats the ball, driving the plug to close and stop venting. If there is a small amount of gas accumulating in the valve during normal operation of the pipeline water to a certain extent, the water level in the valve will drop, and the float will drop accordingly. At this time, the gas will be discharged from the small hole. If the water pump stops and the water in the pipe is empty, negative pressure may occur in the pipe at any time. The float will drop with the water, the small hole will open, and the large hole will be driven to take in a large amount of air to ensure the safety of the pipeline.
 

III. Dimensions  

Nominal Diameter DN D D1 D2 H Z-Φd
50 160 125 205 495 4-18
80 195 160 270 600 4-18
100 215 180 285 460 8-18
150 280 240 340 860 8-22
200 335 395 400 1010 8-22
250 390 350 465 1210 12-22

 

IV. Main Technical Parameters  

Nominal Pressure (Mpa) Test Pressure (Mpa) Applicable Medium Suitable Temperature
Housing Seal
1.0 1.5 1.10

Free of impurities

Clear water, sewage

≤80℃
1.6 2.4 1.76
2.5 4.0 2.75

Keyword

SCAR sewage composite exhaust valve
+
  • SCAR sewage composite exhaust valve

SCAR sewage composite exhaust valve

This product is used at the highest point of the pipeline or in places with trapped air to remove air from the pipe and ensure normal operation. If an air release valve is not installed, the movement of liquid in the pipe will generate heat and cause air to form, resulting in short circuits and reducing the water output capacity of the pipe. Secondly, power outages or pump stoppages during pipe operation can cause negative pressure, leading to pipe vibration or rupture. The air/suction valve quickly draws air into the pipe to prevent pipe vibration or rupture.

Professional valve manufacturing 



Get a Quote

Note: Please leave your contact information, and our professionals will contact you as soon as possible!

Submit message