Fire RVGX grooved concealed stem valve (Z85X)
+
  • Fire RVGX grooved concealed stem valve (Z85X)

I. Structural Features and Applications

Structural Features

  • Optimized Space for Concealed Stem The stem is built-in and not exposed, only driven up and down by rotating the handwheel. The overall height is 20% lower than that of the same diameter exposed stem valve (e.g., DN100 total height 450mm), suitable for narrow spaces such as pipe shafts and basements, meeting the requirements of GB 5135.6-2018 for the compactness of fire valves.
  • Groove Quick Connection The end groove dimensions comply with GB 5135.11-2019 (groove width 11.9mm, groove depth 3.2mm), and are compatible with fire-专用卡箍 (including nitrile rubber sealing gasket). Installation does not require flange bolts; construction efficiency is 30% higher than that of flange connections, meeting the rapid installation requirements for fire pipelines.
  • Elastic Seat Seal The valve disc is completely covered with EPDM rubber (compliant with GB/T 21873-2008), and elastically fits the sealing surface of the valve body. It is sealed by self-tightening with fire water pressure, and the bidirectional leakage rate ≤0.01% (tested according to GB/T 13927-2008), ensuring no medium leakage during a fire.
  • Fire protection coating The valve body is made of ductile iron QT450-10 (inner wall epoxy coating ≥150μm, outer wall fire-engine red coating). The stem is made of 2Cr13 stainless steel (chromium-plated corrosion protection), resistant to long-term immersion in fire water. The handwheel is painted red and marked “消防专用”, meeting the marking requirements of GB 50974-2014.

Applications

Specifically designed for fire systems, used for on-off control of pipelines in automatic sprinkler systems, fire hydrant systems, and fire pump rooms, especially suitable for fire pipelines with limited space (such as pipe shafts and equipment interlayers). It is suitable for clean fire water media and meets the core requirements of fire acceptance for “compact installation, reliable sealing, corrosion resistance and durability.”

 

II. Main Technical Parameters (According to National Standard Conventional Values)

Item Parameter Range
Nominal Pressure (PN) PN16 (1.6MPa, commonly used in fire systems)
Shell Test Pressure 2.4MPa (1.5 times the nominal pressure)
Sealing Test Pressure 1.76MPa (1.1 times the nominal pressure)
Applicable Medium Clean fire water (without obvious particles)
Applicable Temperature (°C) 0~80 (EPDM rubber adaptable)
Nominal Diameter (DN) DN50~200 (conventional diameter of fire groove)
Connection Method Groove type (compliant with GB 5135.11-2019)
Implementation Standard GB 5135.6-2018, GB 50974-2014, GB/T 12232-2005

 

III. Main Parts Materials (Conventional Configuration)

Product Part Material (National Standard Conventional Material)
Valve Body / Valve Cover Ductile iron QT450-10 (epoxy coating on inner wall, fire red coating on outer wall)
Valve Disc Ductile iron + EPDM rubber (overall wrapping, compliant with GB/T 21873)
Valve Stem 2Cr13 stainless steel (quenched and chrome-plated, resistant to fire water corrosion)
Groove End Integrated casting with valve body (compliant with GB 5135.11-2019)
Sealing Element Nitrile rubber NBR (groove seal), EPDM rubber (valve disc seal)
Handwheel Cast iron (red spray paint, with “open/close” and “fire专用” markings)

 

IV. Main External Dimensions and Connections (Unit: mm, according to national standard conventional values)

Nominal Diameter DN

Groove Outer Diameter Dg

Groove Width C

Structural Length L

Total Height H

(Concealed stem fixed)

Handwheel Diameter D0

Adaptable Clamp Specification

Operating Torque

(N・m)

50 60.3 11.9 178 340 180 DN50 ≤80
100 114.3 11.9 229 450 240 DN100 ≤150
150 168.3 11.9 267 570 320 DN150 ≤200
200 219.1 11.9 292 690 400 DN200 ≤250

 

V. Application Scenarios

  • Automatic Sprinkler System Sprinkler main pipe, branch pipe, concealed stem design saves space in the ceiling (compliant with GB 50084-2017).
  • Fire Hydrant System Main pipe, water pump connector branch pipe, fire red marking for easy emergency identification, suitable for pipe shaft installation (compliant with GB 50974-2014).
  • Fire Pump Room Water pump outlet pipe, compact structure suitable for small space in the machine room, ensuring reliable on-off when the water pump is linked.
Fire RVGX grooved concealed stem valve (Z85X)
+
  • Fire RVGX grooved concealed stem valve (Z85X)

Fire RVGX grooved concealed stem valve (Z85X)

Fire RVGX grooved concealed stem valve (Z85X) core advantages: concealed stem design saves space, grooved connection for quick installation, elastic seat seal for zero leakage, fire-grade corrosion resistance and durability. Complies with national fire protection standards, adaptable to PN16, DN50~200, it is a reliable device for "on/off + space optimization" in fire protection systems, meeting fire acceptance and daily safe operation needs.

Professional valve manufacturing 



Get a Quote

Note: Please leave your contact information, and our professionals will contact you as soon as possible!

Submit message