Fire fighting RRGX trench-type gate valve (Z81X)
+
  • Fire fighting RRGX trench-type gate valve (Z81X)

I. Structural Features and Applications

Structural Features

  • Visible Stem Opening The stem rises and falls synchronously with the gate and is fully exposed. The valve opening can be intuitively judged by the length of the stem extension (fully open/fully closed status is clearly visible). This facilitates fire inspection and condition confirmation, meeting the requirements of GB 50974-2014 "Technical Specifications for Fire Water Supply and Fire Hydrant Systems" for monitoring the valve status; the stem uses trapezoidal threads (pitch 3~6mm), providing stable opening and closing torque and easy manual operation.
  • Groove Quick Connection The groove dimensions at the end meet GB 5135.11-2019 "Automatic Sprinkler Fire Suppression Systems Part 11: Grooved Pipe Fittings". It is compatible with fire-specific grooved clamps (including nitrile rubber seals). Installation does not require flange bolts, and pipe connection can be completed within 10 minutes. The construction efficiency is 40% higher than that of flange connection, meeting the emergency installation needs of fire pipelines.
  • Elastic Seat Seal The gate is completely covered with EPDM rubber (compliant with GB/T 21873-2008), forming an elastic fit with the valve body sealing surface. Self-tightening sealing is achieved through fire water pressure. The bidirectional sealing leakage rate ≤0.01% (according to GB/T 13927-2008 Fire Valve Testing Standard) ensures no medium leakage during a fire and is suitable for clean fire water media.
  • Fire-Specific Design The valve body is made of ductile iron QT450-10 (compliant with GB/T 1348-2009). The surface is sprayed with fire-red epoxy coating (thickness ≥150μm), resistant to long-term immersion corrosion by fire water; the handwheel is painted red and marked with "Fire-Specific" identification for quick identification in emergencies, meeting the identification requirements of GB 5135.6-2018 for fire valves.

Applications

Specifically designed for fire systems, used for on/off control of pipelines in automatic sprinkler fire suppression systems, fire hydrant systems, and fire pump rooms, especially suitable for fire pipelines where the opening status needs to be intuitively judged (such as sprinkler mains and fire hydrant mains). It is compatible with clean fire water media and meets the core requirements of fire acceptance for "quick installation, reliable sealing, and visible status".

 

II. Main Technical Parameters (According to National Standard Conventional Values)

Item Parameter Range
Nominal Pressure (PN) PN16 (1.6MPa, commonly used pressure level for fire systems)
Shell Test Pressure 2.4MPa (1.5 times the nominal pressure, according to GB/T 13927-2008)
Sealing Test Pressure 1.76MPa (1.1 times the nominal pressure, according to GB/T 13927-2008)
Applicable Medium Clean fire water (without obvious particulate impurities)
Applicable Temperature (°C) 0~80 (conventional temperature range for fire water, EPDM rubber compatible)
Nominal Diameter (DN) DN50~200 (conventional diameter for fire grooved pipelines)
Groove Standard Compliant with GB 5135.11-2019 (groove width 11.9mm, groove depth 3.2mm, tolerance ±0.1mm)
Implementation Standard GB 5135.6-2018 "Automatic Sprinkler Fire Suppression Systems Part 6: General Valves", GB 50974-2014, GB/T 12232-2005

 

III. Main Component Materials (Conventional Configuration)

Product Part Material (National Standard Conventional Material)
Valve Body/Valve Cover Ductile iron QT450-10 (inner wall epoxy resin spraying, outer wall fire-red epoxy coating)
Gate Ductile iron + EPDM rubber (overall wrapping, rubber hardness 70±5 Shore A, compliant with GB/T 21873)
Stem 2Cr13 stainless steel (tempering treatment, surface chrome plating 0.025mm, resistant to fire water corrosion)
Groove End Integrated casting with the valve body, groove dimensions comply with GB 5135.11-2019, roughness Ra12.5
Groove Seal Nitrile rubber NBR (water-resistant, aging-resistant, compliant with GB/T 5574-2008)
Stem Nut Copper alloy ZCuAl10Fe3 (wear-resistant, opening and closing torque ≤120N・m)
Handwheel Cast iron (surface powder coating, red coating, with "Open/Close" and "Fire-Specific" markings)

 

IV. Main External Dimensions and Connections (Unit: mm, According to National Standard Conventional Values)

Nominal Diameter DN

Groove Outer Diameter Dg

Groove Width C

Structural Length L

(GB 5135.6)

Total Height H1 (Fully Closed)

Total Height H2 (Fully Open)

Handwheel Diameter D0

Operating Torque

(N·m)

Adapter clamp specifications

50 60.3 11.9 178 350 480 180 ≤80 DN50
65 76.1 11.9 190 390 530 200 ≤100 DN65
80 88.9 11.9 203 430 580 200 ≤120 DN80
100 114.3 11.9 229 480 650 240 ≤150 DN100
150 168.3 11.9 267 600 820 320 ≤200 DN150
200 219.1 11.9 292 720 980 400 ≤250 DN200

 

V. Application Scenarios

  • Automatic water spray fire extinguishing system :Main pipe of sprinkler system, front end of zone control valve. The exposed stem design facilitates inspection and confirmation of the "normally open" status. The grooved connection is suitable for quick installation of pipes inside the ceiling (compliant with GB 50084-2017, Article 6.2.7).
  • Fire hydrant system :Main pipe of fire hydrant network, community fire loop network. The red handwheel facilitates quick identification in emergencies, and the exposed stem opening allows for intuitive judgment of whether the valve is normally open (compliant with GB 50974-2014, Article 8.3.1).
  • Fire pump room :Water pump suction pipe, discharge pipe. Grooved connection shortens the installation time of pipes in the pump room, and the exposed stem design facilitates confirmation of the valve status in conjunction with the water pump (adaptable to fire pump room construction specifications).
  • High-rise residential fire pipe network :Branch pipes of fire risers inside the pipe shaft. Grooved connection reduces the space occupied by the pipe shaft, and the exposed stem facilitates daily inspection and maintenance by the property management.

 

Keyword

Fire fighting RRGX trench-type gate valve (Z81X)
+
  • Fire fighting RRGX trench-type gate valve (Z81X)

Fire fighting RRGX trench-type gate valve (Z81X)

The Fire RRGX grooved-type rising stem gate valve (Z81X) is a specialized gate valve manufactured by our company in accordance with national fire protection standards. Key advantages include: visible stem design for easy inspection, grooved connection for quick installation, elastic seat seal to ensure zero leakage of fire water, and red fire protection markings in compliance with regulations. It conforms to GB 5135.6, GB 50974, and other standards, is suitable for PN16, DN50~200, and is specifically designed for fire water systems. It is a reliable on/off device for fire protection networks such as automatic sprinkler systems and fire hydrant systems, meeting the requirements of fire acceptance and daily safe operation.

Professional valve manufacturing 



Get a Quote

Note: Please leave your contact information, and our professionals will contact you as soon as possible!

Submit message