Lockable elastic seat gate valve
+
  • Lockable elastic seat gate valve

I. Structural Features and Applications

Structural Features

  • Anti-theft Locking Design Built-in dedicated locking mechanism (using magnetic or mechanical coded cores), requires a dedicated key to operate, preventing unauthorized adjustment, and meets the anti-theft performance requirements of CJ/T 219-2018 "Municipal Public Valves Soft Seal Gate Valves"; the locking mechanism has undergone 1000 unlocking cycles without failure, and the impact resistance is ≥500N (tested according to GB/T 30038-2013).
  • Elastic Seat Structure The gate is completely covered with EPDM rubber (compliant with GB/T 21873-2008), forming an elastic fit with the sealing surface of the valve body, achieving self-tightening sealing through medium pressure, and the bidirectional sealing leakage rate ≤0.01% (tested according to GB/T 13927-2008), suitable for clear water, tap water, sewage and other non-corrosive media.
  • Underground Adaptability Design The valve body is treated with heavy anti-corrosion (the outer wall is coated with epoxy coal tar or TPEP anti-corrosion layer, thickness ≥300μm), resistant to soil corrosion and stray current, suitable for underground burial or humid environments, and complies with GB/T 50268 Underground Pipeline Construction Specifications; the hidden stem structure (built-in valve stem) saves installation space and prevents deformation from soil compression.
  • Ease of Operation Standard extended valve stem (length can be customized according to the burial depth, 500~2000mm), with a locking device and operating handwheel integrated at the top; the handwheel rotates freely in the locked state (preventing forced operation), and can be normally opened and closed after unlocking; the operating torque is 10%~15% lower than that of ordinary hidden stem gate valves.
  • Connection Method Flange or spigot connection (flange complies with GB 9113-2010, spigot complies with GB/T 13295-2019), the flange surface is equipped with a water stop ring, and the spigot end is equipped with a rubber sealing ring to ensure the sealing of the underground pipeline connection.

Applications

Mainly used for the on/off control of media in underground pipeline systems that require permission control. It can cut off or connect clear water, tap water, sewage and other media. It is suitable for household control of municipal water supply networks (to prevent water theft due to arrears), household management of underground water supply and drainage in communities, key nodes of underground fire pipelines (to prevent misoperation), permission control networks in sewage treatment plants, etc., especially suitable for underground burial, humid, and anti-theft management environments.

 

II. Main Technical Parameters (According to National Standard Conventional Values)

Item Parameter Range
Nominal Pressure (PN) PN10 (1.0MPa), PN16 (1.6MPa)
Shell Test Pressure 1.5 times the nominal pressure (1.5MPa for PN10, 2.4MPa for PN16)
Sealing Test Pressure 1.1 times the nominal pressure (1.1MPa for PN10, 1.76MPa for PN16)
Applicable Media Clear water, tap water, sewage (with a small amount of suspended particles), raw water, etc., non-corrosive media
Applicable Temperature (°C) -10~80 (EPDM rubber conventional operating range)
Nominal Diameter (DN) DN50~1200 (conventional underground pipeline diameter, large diameter can be customized)
Locking Performance Unlocking torque 80~150N・m (increasing with diameter), anti-pry level complies with GB/T 30038-2013 Grade B
Anti-corrosion Grade Outer wall anti-corrosion layer salt spray test ≥3000 hours (complies with SY/T 0442-2014)
Implementation Standards GB/T 12232-2005 (General Gate Valves), GB/T 13927-2008 (Sealing Test), CJ/T 219-2018 (Locking Requirements)

 

III. Main Component Materials (Conventional Configuration)

Product Part Material (Conventional National Standard Material)
Valve Body / Valve Cover Ductile iron QT450-10 (inner wall epoxy resin spraying, outer wall heavy anti-corrosion)
Gate Ductile iron + EPDM rubber (elastic seat seal, complies with GB/T 21873)
Valve Stem 2Cr13 stainless steel (tempering treatment, resistant to soil corrosion)
Locking Mechanism 304 stainless steel core + brass key (anti-corrosion and rust-proof, complies with CJ/T 219)
Extended Rod Carbon steel (galvanized + coated, length customized as required, salt spray resistance ≥1000 hours)
Sealing Element EPDM rubber (water resistant, resistant to soil microorganisms, aging life ≥10 years)
Connecting Flange / Spigot End Ductile iron (flange with water stop ring, spigot end with rubber sealing ring)
Operating Handwheel Cast iron (surface powder coating, with locking hole protective cover, IP65 protection)

 

IV. Main External Dimensions and Connections (Unit: mm, According to National Standard Conventional Values)

Nominal Diameter DN

Flange outer diameter D

(Flange type)

Socket end outer diameter d

(Socket type)

Structural length L

Total height H

(Excluding extension rod)

Extension rod length L1

(Optional)

Handwheel diameter D0

Locking mechanism height h

50 165 63 178 340 500/800 180 50
100 220 118 229 470 500/1000 240 60
200 340 222 292 700 800/1500 400 80
300 460 326 356 970 1000/2000 560 100
600 780 630 540 1530 1500/2500 800 120
1000 1110 1026 710 2250 2000/3000 1000 150

 

V. Application scenarios or fields

Underground pipe network control scenarios

  • Municipal water supply to households :Pipe installation after the community's main meter, using the locking function to achieve "pay first, then use water", when overdue, close with a special key to avoid the cost of manual inspection (in accordance with GB 50268 Underground Pipeline Construction Specifications).
  • Heating sub-metering control :Branch pipes of the centralized heating system, the shut-off valve is used with the heat meter, unpaid users can be remotely shut off, and opening requires a special authorized key (adaptable to CJ/T 379 heat metering system).
  • Underground fire-fighting pipes :Outlet pipe of the fire water pool or main pipe of the sprinkler system, usually locked to prevent accidental opening and water loss, and quickly opened with a special key from the fire control room in case of fire (in accordance with GB 50974 Fire Protection Specifications).
  • Sewage pipe network maintenance :Zoning pipes of the sewage treatment plant, isolation is locked during maintenance to prevent unauthorized personnel from misoperation and causing leakage, and the locking mechanism is resistant to sewage corrosion (in accordance with GB 50014 Sewage Treatment Design Specifications).
Lockable elastic seat gate valve
+
  • Lockable elastic seat gate valve

Lockable elastic seat gate valve

Based on underground resilient seated gate valves, the locking resilient seated gate valve adds a dedicated locking mechanism to achieve access control. It retains the reliable sealing (zero leakage) and corrosion resistance of resilient seated valves suitable for underground environments, while also solving unauthorized operation issues through anti-theft locking. It is produced according to national standard conventional standards, using durable materials such as QT450-10 ductile iron, covering PN10/PN16 pressure levels and DN50~1200 diameters. It adapts to the "sealing + control" dual needs of municipal water supply, heating, fire protection, and sewage underground pipe networks, and is a practical valve product that ensures the safe and efficient operation and management of underground pipeline systems.

Professional valve manufacturing 



Get a Quote

Note: Please leave your contact information, and our professionals will contact you as soon as possible!

Submit message