Return to List

Z45X Flanged Non‑Rising Stem Resilient‑Seated Gate Valve | GTF Ductile Iron Isolation Valve

GTF Z45X flanged non‑rising stem resilient‑seated gate valve for municipal water & wastewater pipelines. Ductile‑iron body, DN50‑DN400, PN10‑PN25, reliable bubble‑tight shut‑off for confined‑space installations.

2026-09-01

Z45X Flanged Non‑Rising Stem Resilient‑Seated Gate Valve | GTF Ductile Iron Isolation Valve

Introduction

Traditional metal‑to‑metal gate valves often suffer from poor sealing performance, medium leakage and component rust after long‑term service. For municipal water networks, underground valve chambers and building piping projects with limited vertical clearance, space‑saving isolation valves with dependable shut‑off capability are highly demanded.

GTF Z45X‑10Q / 16Q / 25Q flanged non‑rising stem resilient‑seated gate valve adopts an internally‑hidden stem structure together with rubber‑encapsulated wedge gate. It delivers tight shut‑off while occupying less installation height. Manufactured per GB/T industry standards, this manual ductile‑iron gate valve serves as a preferred shut‑off solution for water and non‑corrosive‑gas pipelines across multiple industries.

Working Principle

By rotating the handwheel, threaded engagement drives the wedge gate to move up and down inside the valve body. The stem only rotates without extending outward, so overall valve height stays unchanged during full‑open / full‑closed travel. The integrated NBR rubber lining on the wedge generates deformation compensation to achieve reliable sealing effect.

 

Core Product Advantages

  1. Space‑Saving Non‑Rising‑Stem (NRS) Construction The stem stays fully housed inside the bonnet. No extra vertical clearance is required for stem extension. Perfect for underground valve pits, pipe shafts and compact equipment‑room layouts.
  2. Resilient‑Sealed Wedge for Tight Shut‑off The ductile‑iron wedge is fully encapsulated with NBR rubber. Deformation compensation eliminates common leakage risks seen on conventional metal‑seat gate valves. It provides stable isolation performance for water‑system pipelines.
  3. Robust Ductile‑Iron Main Body Valve body, bonnet and handwheel are made of high‑strength ductile iron. The 20Cr13 stainless‑steel stem resists rust and abrasion. Multiple NBR O‑rings and gaskets guarantee stem and joint sealing performance.
  4. Standard‑Compliant Flanged Interface Flange dimensions, face‑to‑face length and inspection procedures follow GB/T specifications. Interchangeable with most existing flanged piping systems, convenient for both new‑build projects and pipeline retrofits.
  5. Simple Manual Operation & Strict Factory Verification Handwheel‑driven manual operation brings straightforward on‑site control. Every unit goes through complete factory pressure and functional tests before shipment. Relevant documentation can be provided for project review.

Note: This valve is designed for shut‑off service. Continuous throttling for flow or pressure regulation is not recommended.

Technical Specifications

 

ParameterDetails
ModelZ45X‑10Q / 16Q / 25Q
Valve TypeFlanged Non‑Rising Stem Resilient‑Seated Gate Valve
Nominal SizeDN50 ~ DN400
Pressure RatingPN10 (1.0 MPa), PN16 (1.6 MPa), PN25 (2.5 MPa)
End ConnectionFlanged, compliant with GB/T 17241.6‑2008
Operation ModeManual handwheel
Body / Bonnet MaterialDuctile Iron
WedgeQT450‑10 with NBR rubber lining
Stem20Cr13 stainless steel
Sealing ElementsNBR (O‑rings, gaskets)
Applicable MediaWater, non‑corrosive gas
Face‑to‑Face StandardGB/T 12221‑2005 Series 3
Test StandardGB/T 13927‑2008

 

Typical Application Scenarios

  • Municipal Water & Wastewater: Urban water‑supply mains, distribution networks, wastewater treatment facilities, underground valve chambers
  • Building Systems: Building water‑supply pipelines, HVAC circulating‑water lines, pipe‑shaft installations with height constraints
  • General Industry: Food & beverage, pharmaceutical, textile, power, metallurgy and energy‑system fluid pipelines for isolation duties

Installation & Operational Guidelines

  1. Rubber sealing components shall avoid long‑term outdoor storage and direct sunlight exposure to prevent rubber aging.
  2. Never use handwheel or transmission parts as lifting points; protect against mechanical impact.
  3. Pre‑weld pipeline flanges before valve installation. Do not perform welding operations while the valve is clamped on‑line, as hot welding spatter can damage rubber sealing surfaces.
  4. Thoroughly clear welding slag, metal chips and debris inside pipelines prior to installation.
  5. Tighten flange‑connection bolts evenly in cross sequence. Overtorquing may tilt sealing faces and cause leakage.
  6. Mount in vertical or horizontal orientation. Inverted installation is discouraged to avoid debris accumulation inside body cavity.
  7. After installation, cycle the valve 2‑3 times with no load to confirm smooth mechanical movement. Fully open the valve and flush pipelines at maximum flow rate to wash away residual foreign particles.
  8. Do not apply excessive force or over‑long extension bars to open valves kept fully closed for a long period; this may harm sealing components.
  9. For frequently cycled units, carry out regular lubrication at minimum monthly intervals. Drain internal water for idle valves under low‑temperature conditions to prevent freeze‑cracking.
  10. All disassembly and maintenance work must be executed only after full pipeline depressurization.

Frequently Asked Questions

Q1: Can this Z45X gate valve be used for throttling flow?

A: Not recommended. This resilient‑seated NRS gate valve is engineered for full‑open / full‑closed shut‑off service. Long‑term partial‑opening throttling will accelerate rubber‑seal wear.

Q2: What media can this valve handle?

A: Designed for water and non‑corrosive gas. Not suitable for strong‑corrosive, high‑temperature or particle‑heavy working fluids.

Q3: Are dimensional drawings and test records available?

A: Yes. We can offer dimension drawings, product certificates and factory test records to support your project acceptance process.

Q4: Is underground‑chamber installation supported?

A: Yes. Thanks to the non‑rising‑stem compact profile, it is widely adopted for underground valve‑chamber projects. Ensure sufficient working space is reserved for operators.

 

Get In Touch

If you need quotations, datasheets or further technical support for Z45X resilient‑seated gate valves for your water‑system projects, please reach out to our technical‑sales team.

Official Website: www.gaotejituan.com 

Email: gaotegroup@126.com 

Tel: +86‑13400888017

GTF delivers standardized, fully‑tested ductile‑iron valve solutions for municipal and industrial fluid‑control projects.