Traffic switch
+
  • Traffic switch

I. Core Structural Features (with illustrations)

  1. Flange Connection Design :The valve body uses National Standard Flange Connection (Compliant with GB/T 9119, Flat and Raised Face Integral Steel Pipe Flanges), the flange sealing surface and bolt hole layout are compatible with the national standard pipeline system, ensuring connection sealing and universality.
  2. Main Material and Process :The valve body uses **Ductile Iron (QT450-10)** casting (implementing GB/T 12227, General Valves - Technical Conditions for Carbon Steel Castings), with anti-corrosion spray coating on the surface, pressure-resistant and impact-resistant, suitable for high-pressure conditions such as fire protection and industrial fluids.
  3. Sensing and Display Integration :Equipped at the top with Electronic Display Control Unit (including LCD screen and operation buttons), real-time display of flow data; a sensor installation interface is provided on the side (wiring terminals and sensor structure are visible in the picture), the sensor adopts an insertion design, with sensitive response, conforming to the installation and signal transmission requirements of GB/T 32246 Thermal Flow Switches.
  4. Sealing System Design :The valve body and flange use Nitrile Rubber Gasket (Compliant with GB/T 3452.1, Hydraulic and Pneumatic O-ring Rubber Seals), combined with bolt fastening structure, ensuring zero leakage of medium, meeting the sealing performance requirements of GB/T 13927, Industrial Valves - Pressure Test.

 

II. Main Technical Parameters (National Standard)

Parameter Name Value / Range Unit National Standard Basis
Nominal Pressure 1.6 MPa GB/T 1048 Nominal Pressure of Pipeline Components
Applicable Medium Water, fire water, low-corrosive liquid - GB 50974 Technical Specifications for Fire Water Supply and Fire Hydrant Systems, GB 50015 Design Standard for Building Water Supply and Drainage
Flow Range 0.5~100 m³/h GB/T 32246 Thermal Flow Switch
Operating Temperature 0~80 GB/T 12221 Metal Valves - Structural Length
Accuracy Grade ±2%FS - GB/T 18268 Electromagnetic Compatibility Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use
Protection Grade IP65 - GB/T 4208 Degree of Protection Provided by Enclosures
Response Time ≤5s s Product Design Specification (conforms to the response speed requirements of the flow switch industry)
Output Signal Passive Contact (Normally Open / Normally Closed) - GB/T 14048.5 Low-voltage switchgear and controlgear - Control circuit devices and switching elements

 

III. Main Part Materials (National Standard)

Part Name Material Implementation Standard
Valve Body, Flange Ductile Iron QT450-10 GB/T 12227
Sensor Element 304 Stainless Steel GB/T 1220 Stainless Steel Bars
Sealing Gasket Nitrile Rubber NBR GB/T 3452.1
Display Unit Housing Cast Aluminum (Surface Coating) GB/T 1173 Cast Aluminum Alloys
Fasteners (Bolts / Nuts) 304 Stainless Steel GB/T 3098.1 Mechanical Properties of Fasteners - Bolts, Screws and Studs

 

IV. Dimensions and Specifications (National Standard)
(Note: Flange dimensions comply with GB/T 9119-2010 PN16 Flat and Raised Face Integral Steel Pipe Flanges, structural length refers to GB/T 12221 Metal Valves - Structural Length)

Specifications and Models

Nominal Diameter

DN (mm)

Flange Outer Diameter

D (mm)

Bolt Hole Center Distance

K (mm)

Number of Bolt Holes

n (pcs)

Bolt Hole Diameter

d (mm)

Structural Length

L (mm)

GT-LLKG 50 165 125 4 18 200
GT-LLKG 80 200 160 8 18 250
GT-LLKG 100 220 180 8 18 300
GT-LLKG 150 285 240 8 22 355
GT-LLKG 200 340 295 12 22 400
GT-LLKG 250 405 355 12 26 450
GT-LLKG 300 460 410 12 26 500

 

V. Typical Application Scenarios

  1. Firefighting System In automatic sprinkler fire extinguishing systems, it monitors the water flow status in real time, and triggers a signal to start the fire pump in case of fire, complying with the "GB 50974 Technical Specifications for Fire Water Supply and Fire Hydrant Systems".
  2. Building Water Supply and Drainage Flow monitoring and control of urban water supply and drainage networks, suitable for metering and safety prevention scenarios in accordance with "GB 50015 Design Standard for Building Water Supply and Drainage".
  3. Heating Flow detection of hot water circulation networks to prevent interruption or excessive flow, meeting the requirements of "GB 50736 Design Code for Heating, Ventilation and Air Conditioning of Civil Buildings".
  4. Wastewater Treatment Inlet flow control of wastewater treatment plant process sections (such as aeration tanks and sedimentation tanks), complying with "GB 50334 Acceptance Standard for Engineering Quality of Urban Wastewater Treatment Plants".
  5. Industrial Cooling Flow monitoring of industrial equipment cooling water circulation systems to ensure stable heat dissipation, suitable for "GB 50050 Design Code for Industrial Circulating Cooling Water Treatment".

Keyword

Traffic switch
+
  • Traffic switch

Traffic switch

The flow switch uses a national standard flange connection (GB/T 9119) and a ductile iron body (GB/T 12227), integrating a high-precision sensor and electronic display unit. The flow monitoring accuracy reaches ±2% FS, and the protection level is IP65. It is suitable for various fields such as fire protection, water supply and drainage, heating, and industrial cooling. It monitors fluid flow in real time and outputs switching signals, providing reliable protection for the safe and efficient operation of the system. It is a national standard compliant core component for industrial and civil pipeline flow control.